The grease interceptor is designed totrap greases contained in effluents, by means of gravity.


 A complete range to meet your needs




Grease interceptors must comply with various standards with respect both to their construction and dimensioning.

MaterialsRated size
STAINLESS STEEL1 to 15
POLYESTER20 to 70
POLYETHYLENE1 to 28


 Operating principle




Click to enlarge

It is based on the density difference between the particles inside the grease interceptor.

Greases, with a density of 0.95, rise to the surface while heavy matter with a density of 1.1 settle to the bottom of the interceptor.

The grease-containing water arrives in the interceptor through the inlet device (1), fitted with an anti-splash nozzle to avoid stirring up the sludge and grease that have already decanted out (2).

The partition (3) retains the sludge in the first part and the outlet siphon (4) keeps the grease inside the interceptor.


 Equipment



 The sludge trap


The compartment located upstream the interceptor is designed to trap heavy matters (sludge). Its volume meets the volume defined in standard NF EN 1825-1.

 The separator


The compartment is dimensioned to comply with the following criteria (defined in the standard):

Grease separating area
Minimal surface areaMinimum volume (m3)Minimum storage volume (m3)
0,25 x TN0,24 x TN0,04 x TN